this post was submitted on 23 Oct 2024
13 points (100.0% liked)
Futurology
1793 readers
54 users here now
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
I believe this type of motor could have very low power consumption while holding position without relying on non-backdriveable mechanics. That isn't stated in the article so I could be wrong. If that's the case, I could see this type of motor being valuable in servo/stepper type applications. Servos and especially steppers, run hot even when just holding torque since the coils have to stay energized.
A major concern would be ensuring no contamination. Any FOD, or metal filings generated from wear and tear could ruin such a motor.
That's an interesting point. It also implies much better efficiency at low speeds than most motors.
Given a few generations of better semiconductor, it could end up being very interesting for (railway mostly?) traction motors.
Low speed high torque means you don't need a further reduction gearbox.
Good performance near zero speeds mean you might not need to use braking at all aside from parking and emergencies.
High voltages are already widely used and available - 1500VDC nominal is an older standard for metro trains; 3kVDC is common both for older overhead and as an intermediate DC bus voltage for AC overhead. Future semiconductor generations could allow direct use of 25kV overhead (~40kVDC rectified at maximum line level) without the need for an intermediate bus, assuming the dielectric fluid was good enough.