I am wiring this up, and I would like to limit the current being drawn from 18v DC/DC converter.

What would be the simplest way of doing this?

you are viewing a single comment's thread
view the rest of the comments
[–] boojumliussnark@lemmy.world 1 points 1 week ago (1 children)

Oh, wow!

Very nice! Thank you so much for doing this!

Is it correctly understood that the "Sense" line can be hooked up directly to the ADC input on the Pico?

Now, just because I am quite ignorant when it comes to all this, I will venture to ask: This is better because it is closer/faster/more exact than using the Hall current sensor, or? With my complete lack of understanding, I had the impression, that I could more or less "just" connect the sensor to the "right spots" and directly to the ADC input on the Pico, and my work in the Pico would be similar to this setup?

Don't get me wrong - I can see this is much more elegant - and won't be bothered by whatever else might use power on the same rail. But since it might be simpler for me to use a more "out of the box" component like the sensor, instead of my bad soldering of several discrete components... Also however ridiculous it might seem it is much easier for me to source 5 modules - than 5 of each of these components (I would have to buy many of each, and waste most).

So I have to ask. :-)

[–] cmnybo@discuss.tchncs.de 2 points 1 week ago (1 children)

The sense output from the op amp connects directly to an ADC input. The output is 1 volt per amp. If sense_a is already connected to ground, you will have to disconnect it.

The hall effect current sensor will work fine too. They do tend to have an offset, but you can calibrate that out in software. Just take a reading when the motor is off and subtract it from the reading when the motor is on. If you do use the hall effect sensor, you could connect it between sense_a and ground so it will only measure the motor current.

[–] boojumliussnark@lemmy.world 1 points 1 week ago (1 children)

Thanks again!

Does this look OK, to your trained eye then?

[–] cmnybo@discuss.tchncs.de 2 points 1 week ago (1 children)

Yes, that is wired correctly.

Did you get the 5 amp current sensor or the 30? The higher current ones output less voltage per amp, which will make it harder to measure small currents.

[–] boojumliussnark@lemmy.world 1 points 1 week ago (1 children)

I got the 30 amp. My thought was that the motor uses up to around 20 watts when running so a little more than 1 amp, and as far as I can tell, it tries to pull around 6-10 amps(!) when stalled/almost stalled. I think this should mean a fairly large spike, that I should be able to detect even with the 30A device.

But of course it is probably just absurd overkill, and will make my life more complicated. Fortunately they are absurdly cheap and easy to buy, so if the resolution turns out to be a problem, I can get another range, when I have some empirical data. The other ranges should plug in, in the same place right?

[–] cmnybo@discuss.tchncs.de 2 points 1 week ago

The other ranges connect exactly the same.